UaGateway from Unified Automation GmbH connects Classic OPC applications with OPC UA systems. Manufacturing teams in India can use it to connect new applications to existing OPC servers or retain HMI/SCADA clients when upgrading the systems behind them.
Equipment data reaches UaGateway through an existing OPC server or a controller's own OPC interface. Direct PLC communication depends on that underlying connection.
As a wrapper, UaGateway connects locally to a Classic OPC server and exposes its data to OPC UA clients. As a proxy, it makes data from OPC UA servers available to a legacy OPC DA client, such as an HMI or SCADA application. Either approach allows one side of a connection to be upgraded while the other remains in use.
A tunnel uses two UaGateway installations, one beside each Classic OPC application. The applications communicate locally through COM; the gateways exchange data over OPC UA with authentication and encryption.
The connection between computers therefore uses OPC UA instead of remote DCOM. Firewall rules, certificate trust and user permissions remain part of the network configuration.
UaGateway combines data from multiple underlying OPC servers into one OPC UA access point. Upper-level applications connect to the gateway rather than maintain a separate connection to each source.
Recovery from a source-server or gateway failure needs a separate design. Aggregation does not, by itself, provide failover.
UaGateway addresses plant upgrades where an existing OPC interface must remain available during migration. Examples include adding an MES connection to a production line or replacing a data source while keeping the existing SCADA client.
A site with separate OPC servers for different production areas can also consolidate access through a gateway. Compatibility depends on those servers' interfaces, rather than the equipment manufacturers alone.
Projects that still need direct PLC connectivity require a device connectivity product. The OPC NEXUS guide covers that broader selection.
| Supported Protocols: | OPC UA / OPC DA 2.05a and 3.0 / OPC A&E 1.1 and OPC HDA 1.2 through additional features. The official download information also lists XML-DA server connectivity. Availability depends on the connection direction and feature keys. |
|---|---|
| Pricing Guide and Fee Structure: | Runtime licensing per installation, with additional feature keys for optional functions. Contact Unified Automation for current pricing. |
UaGateway connects to existing OPC servers and exposes their information through its own server interfaces. The required configuration depends on each application's role as a client or server and the data it exchanges.
Some source information has mapping limits. The version 1.7.3 documentation states that vendor-specific COM DA properties are not passed through to OPC UA. It also states that historical access exposes raw data, without the aggregates provided by underlying COM HDA servers. Applications using either need a compatibility test.
The base Data Access feature provides browsing, reading, writing and monitoring. Separate feature keys enable the following functions:
UaGateway also supports Reverse Connect, allowing a connection to be initiated from the protected network side. The deployment must permit the required outbound traffic.
UaGateway runs as a 32-bit Windows service and operates on 64-bit Windows through WOW64. Installation requires administrator rights. Confirm support for the intended Windows edition and build before deployment.
Unified Automation recommends placing UaGateway on the same computer as the Classic OPC COM client or server. Remote DCOM configuration is outside its support scope, and only one UaGateway installation can run on a PC.
Standard runtime licensing applies per installation. For a quotation, provide the deployment computers or virtual machines, connection topology and required features. Buyers in India should also confirm the purchasing route, support arrangements and maintenance terms.
Unified Automation's September 2012 case study describes UaGateway's use at Valio, a Finnish dairy processor.
Valio needed to connect production data to MES and enterprise applications across automation systems from different vendors. Classic OPC was already established at production level, but communication across network boundaries created administration and security problems.
After prototype testing, Valio selected UaGateway for its OPC UA integration backbone. Prosys connected legacy OPC servers with UA clients while retaining existing production communication and network infrastructure. Following this work, Valio decided to extend OPC UA integration gradually across 15 production sites.
The Valio approach offers a starting point for an Indian plant with established OPC systems: map the production-to-MES data path, identify the network boundaries, and test a representative connection before expanding. The case demonstrates a migration approach; it does not document an Indian deployment.
Unified Automation offers an evaluation download with a one-hour runtime limit; the software can be restarted. Registration and login are required. This runtime limit is separate from the manufacturer's general evaluation licence period.
Test browsing and any required writes, along with values, timestamps and quality information. Include connection loss and recovery, plus alarm or history behaviour where needed. For longer uninterrupted acceptance testing, discuss evaluation terms with Unified Automation.
Unified Automation GmbH supplies OPC UA software, development tools and runtime products. The OPC Foundation lists it as a Corporate Member.
| Company Name | Unified Automation GmbH |
|---|---|
| Headquarters Address | An der Kaufleite 34, D-90562 Kalchreuth, Germany |
| Enquiries from India | Contact Unified Automation for the sales and support contact responsible for your project in India. |
| Official Website | https://www.unified-automation.com/ |
| Product and Contact Pages | UaGateway Product Information Pricing and Technical Enquiries |
Advertiser Disclosure:
We receive compensation from some of the companies listed below.This compensation may affect which companies are included and the order in which they appear.
Communication parameters can be changed dynamically while the server keeps running, so adding a device or revising a setting does not interrupt data collection. Drivers cover 400+ device series from 100+ manufacturers, including Siemens, Rockwell Automation, Mitsubishi Electric and Omron, so most equipment changes are handled as a setting change rather than a rebuild.
Every site publishes data through OPC UA, or sends it to AWS, Azure and other cloud services over MQTT or HTTP*, so upper systems see the same interface wherever the data originates. A cloud-side OPC UA client can initiate the connection, so no inbound ports need to be opened at the site. Calculation, conditional branching and recipe handling are configured on the server itself at no additional cost, keeping that work off the SCADA or MES side.
Packaged licensing* for large-scale standardization reduces the need to procure licenses when adding new sites or manage updates site by site. This supports scaling while maintaining the management framework.
With add-on options, OPC servers running at different sites can be centrally managed from the main site.
Collects oil and gas drilling data via OPC. Secure transmission across firewalls and redundancy help maintain an audit-ready data foundation over time.
All servers include diagnostic logging with log-level settings and filtering. The logs can also serve as a foundation for audit trails.